Polytec Energy, with the “H2_Polytec” project, has been selected among the winners of the provincial call issued by the Autonomous Province of Trento for the development of a green hydrogen production plant in decommissioned industrial areas, as part of Mission 2 “Green Revolution and Ecological Transition” of the Italian National Recovery and Resilience Plan (PNRR).
This playlist compiles all the construction phases of the H2_Polytec project, documented step by step. From the initial work on-site to the installation of the main systems, each video shows the project’s progress, highlighting the technologies, construction processes, and key milestones.
| 1 | DG2092 distribution cabin |
| 2 | Control and distribution cabin |
| 3 | Transformer room |
| 4 | Service room |
| 5 | Nitrogen generator and air compressor |
| 6 | Electric & control unit weight: 20.000 kg |
| 7 | Process unit weight: 25.000 kg |
| 8 | Area designated for future expansion of the electrolyzer |
| 9 | Storage 30m3 - 30 bar - 71 kg - h 3.3m |
| 10 | Storage 30m3 - 30 bar - 71 kg - h 3.3m |
| 11 | 85-meter underground fire suppression tank3 |
| Water in | |
| Water out | |
| Nitrogen | |
| Compressed air | |
| Electrical distribution and signals | |
| Hydrogen distribution | |
| Wastewater | |
| Firefighting water | |
| Connection area |
Via Primo Maggio, Storo (TN)
Used to generate green energy
Via Roma 151, Borgo Chiese (TN)
System type: Canopy
Connection type: Connected to the public distribution network
Nr. 5 storage LUNA2000-215-2S10_215KWH
Località al Ponte, Cimego (TN)
System type: Rooftop
Connection type: Connected to the public distribution network
Via Primo Maggio, Storo (TN)
System type: Ground and rooftop
Connection type: Connected via private power line
Via Primo Maggio, Storo (TN)
System type: Canopies
Connection type: Connected via private power line
Via Roversella, Storo (TN)
System type: Ground-mounted with tracker
Connection type: Interconnected via private power line
Nr. 1 container storage LUNA2000-1.0MWH-1H1
Nr. 1 container storage LUNA2000-2.0MWH-2H1
DC_LV_Panel
Via Condini, Storo (TN)
System type: Ground-mounted with tracker
Connection type: Interconnected via private power line
Nr. 1 container storage LUNA2000-2.0MWH-2H1
DC_LV_Panel
Provincial Resolution – Autonomous Province of Trento no. 24 of January 13, 2023: Public call aimed at selecting project proposals for the development of renewable hydrogen production plants in decommissioned industrial areas, funded under the National Recovery and Resilience Plan (PNRR), Mission 2 “Green Revolution and Ecological Transition”, Component 2 “Renewable Energy, Hydrogen, Grid and Sustainable Mobility”, Investment 3.1 “Production in Decommissioned Industrial Areas”, financed by the European Union – Next Generation EU.